ELECTRICAL
4-52
5400 330735 (3–01)
3. Loosen the worm drive clamp on the small
outlet hose on the ES
pump. Remove the
hose.
4. Remove the ES
pump from the tank by
un–screwing it counter–clockwise.
5. Put water proof thread sealant on the
threads of the new ES
pump.
6. Screw the new pump clockwise into the
recovery tank. Tighten until the outlet tube
points towards the back of the machine.
7. Re–connect the small water line and worm
drive clamp to the ES
pump.
8. Re–connect the main wire harness to the
new pump. See schematic in the
ELECTRICAL section of this manual.
9. Close the recovery tank, operate the
machine and check the ES
pump for
proper operation.
Содержание 5400