ELECTRICAL
4-55
5400 330735 (3–01)
ELECTRIC MOTORS
The carbon brushes on the vacuum fan motor,
scrub brush motor, and propelling motor should be
inspected after every 400 hours of machine
operation.
TO REPLACE VACUUM FAN MOTOR
BRUSHES
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
1. Remove the vacuum fan from the machine.
See TO REMOVE VACUUM FAN
instructions in this section.
2. Pry back the locking tabs and remove the
fan motor cover.
NOTE : DO NOT operate vacuum fan with the top
cover removed.
3. Remove the two pan head screws holding
the clamp and motor brushes in place.
Remove the brushes and measure.
NOTE: If the motor brushes measure 10 mm
(0.375 in.) of an inch or less in length, install
new brushes.