AZ
2
USER MANUAL
ST.TEC.003.EN Rev. 2.1
44 / 52
S208
Motor 2
High threshold of inrush current control during
homing
1 – 20 [A]
10
S209
Motor 2
Low threshold of inrush current control during
homing
1 – 19 [A]
9
S210
Motor 2
Delay of inrush current control during homing
1 – 500 [ms]
10
S211
Motor 2
Delay added to open acceleration time before
the normal threshold is applied
100 – 1500 [ms]
1000
S212
Motor 2
High threshold of nominal current control
during homing
1 – 11 [A]
5
S213
Motor 2
Low threshold of nominal current control
during homing
1 – 10 [A]
4
S214
Motor 2
Delay of nominal current control during
homing
1 – 500 [ms]
10
S215
Motor 2
Inertial braking time after overcurrent
500 – 3000 [ms]
500
S216
Motor 2
Open approaching voltage
1 – 48 [V]
5
S217
Motor 2
Close approaching voltage
-1 – -48 [V]
-5
S218
Motor 2
Pulses for braking advance
1 – 32000
1
S219
Motor 2
Tolerance used for the limit detection
0 – 500
2
S220
Motor 2
Duration of the braking after limit is reached
100 – 1000 [ms]
500
Table 38: synchronism motor specific parameters