AZ
2
USER MANUAL
ST.TEC.003.EN Rev. 2.1
9 / 52
1.7.
Maintenance and inspection
!
WARNING
Do not replace parts. This could be a cause of electric shock, fire and bodily
injury. To replace parts, call your TeMec Drive distributor.
!
The equipment must be inspected periodically. If the equipment is not inspected
and maintained, errors and malfunctions may not be discovered and that could
result in accidents.
Before inspection, perform the following steps:
1.
turn off all input power to the drive;
2.
wait at least 5 minutes and check to make sure that the on state LED1 is no longer
lit;
3.
use a tester that can measure DC voltages (60V DC or more), and check that the
voltage to the DC main circuits (V and 0V) is 45V or less.
Performing an inspection without carrying out these steps first could lead to
electric shock.
1.8.
Disposal
!
WARNING
!
If you dispose of the drive, have it done by a specialist in industry waste disposal
(*). If you dispose of the drive by yourself, this can result in explosion of capacitor
or produce noxious gases, resulting in injury.
(*) Persons who specialize in the processing of waste and known as "industrial waste
product collectors and transporters" or "industrial waste disposal persons”. Please
observe any applicable law, regulation, rule or ordinance for industrial waste
disposal.
1.9.
CE conformity and applicable standards
The AZ2 drive complies with the following standards:
EMC CE-Emission of interference according to EN 61000-6-4: 2007
EMC CE-Immunity to interference according to EN 61000-6-2: 2005
The drive is a component to be used in a second environment (industrial environment) and category
C3, together with specific EMC filters. When used in the first environment (residential / commercial
environment), drives may produce radio-frequency interference dangerous for other equipment: the
user must implement additional filtering measures.