USER MANUAL
ST.TEC.003.EN Rev. 2.1
34 / 52
For example, the advanced parameter for motor 1 are (see 8.4 for the complete list):
Label
Output
Function
Range
Default
value
SG05
Both
Increment of deceleration start pulses
0 – 8
1
S100
Motor 1
Close limit pulses number
-2147483647
–
2147483647
0
S102
Motor 1
Open limit pulses number
-2147483647
–
2147483647
1000
S116
Motor 1
Open approaching voltage
1 – 48 [V]
5
S117
Motor 1
Close approaching voltage
-1 – -48 [V]
-5
S118
Motor 1
Pulses for braking advance
1 – 32000
1
S119
Motor 1
Tolerance used for the limit detection
0 – 500
2
S120
Motor 1
Duration of the braking after limit is reached
100 – 1000 [ms]
500
Table 22: example of synchronism advanced parameters
Another parameter accessible by the user regards the speed calculation but is recommended not to
change it:
Label
Function
Range
Default
value
SG04
Speed N bit sampling
0 – 32
7
Table 23: speed calculation advanced parameter