Synchronism - global
!
Read carefully the safety precautions reported in 1.6 before modifying any of the
advanced parameters!
The highlighted parameters are accessible only in advanced mode.
Label
Function
Range
Default
value
SG00
Enables the synchronous operating mode
ON / OFF
-
SG01
Enables automatic homing at start-up
ON / OFF
OFF
SG02
Enables current detect homing
ON / OFF
ON
SG03
Compensation strength
1 – 32000
1024
SG04
Speed N bit sampling
0 – 32
7
SG05
Increment of deceleration start pulses
0 – 8
1
Table 39: synchronism global parameters
8.6.
Independent with encoder
Label
Function
Range
Default
value
GES3
Defines which motors are equipped with the encoder
in indep. with encoder mode
0 – 3
0
IEH1
Enables automatic homing at start-up for motor 1
ON / OFF
OFF
IEH2
Enables current detect homing for motor 1
ON / OFF
ON
IEH3
Enables automatic homing at start-up for motor 1
ON / OFF
OFF
IEH4
Enables current detect homing for motor 1
ON / OFF
ON
Table 40: independent with encoder parameters
8.7.
Global errors
!
Read carefully the safety precautions reported in 1.6 before modifying any of the
advanced parameters!
The highlighted parameters are accessible only in advanced mode.
Any change to the parameters of these groups take effect only after the drive restart.
The parameters associated to the under-voltage error are:
Label
Function
Range
Default
value
AU00
If enabled, the drive blocks in case of error
ON / OFF
ON
GES7
Value of the minimum supply voltage (percentage of
the supply voltage)
0 – 100 [%]
90
AU03
Delay of the error detection
1 – 2000 [ms]
500
Table 41: undervoltage error parameters