AZ
2
USER MANUAL
ST.TEC.003.EN Rev. 2.1
41 / 52
C109
Motor 1
Low threshold of nominal current control
during opening
1 – 10 [A]
9
C110
Motor 1
Delay of nominal current control during
opening
1 – 500 [ms]
20
C112
Motor 1
Enables the soft start function during closing
ON / OFF
ON
C113
Motor 1
Enables the block in case of inrush overcurrent
during closing
ON / OFF
ON
C114
Motor 1
High threshold of inrush current control during
closing
1 – 20 [A]
20
C115
Motor 1
Low threshold of inrush current control during
closing
1 – 19 [A]
19
C116
Motor 1
Delay of inrush current control during closing
1 – 500 [ms]
20
C118
Motor 1
Delay added to close acceleration time before
the normal threshold is applied
100 – 1500 [ms]
1000
C119
Motor 1
Enables the block in case of overcurrent during
closing
ON / OFF
ON
C120
Motor 1
High threshold of nominal current control
during closing
1 – 11 [A]
10
C121
Motor 1
Low threshold of nominal current control
during closing
1 – 10 [A]
9
C122
Motor 1
Delay of nominal current control during closing 1 – 500 [ms]
20
C200
Motor 2
Enables the soft start function during opening
ON / OFF
ON
C201
Motor 2
Enables the block in case of inrush overcurrent
during opening
ON / OFF
ON
C202
Motor 2
High threshold of inrush current control during
opening
1 – 20 [A]
20
C203
Motor 2
Low threshold of inrush current control during
opening
1 – 19 [A]
19
C204
Motor 2
Delay of inrush current control during opening 1 – 500 [ms]
20
C206
Motor 2
Delay added to open acceleration time before
the normal threshold is applied
100 – 1500 [ms]
1000
C207
Motor 2
Enables the block in case of overcurrent during
opening
ON / OFF
ON
C208
Motor 2
High threshold of nominal current control
during opening
1 – 11 [A]
10
C209
Motor 2
Low threshold of nominal current control
during opening
1 – 10 [A]
9
C210
Motor 2
Delay of nominal current control during
opening
1 – 500 [ms]
20
C212
Motor 2
Enables the soft start function during closing
ON / OFF
ON
C213
Motor 2
Enables the block in case of inrush overcurrent
during closing
ON / OFF
ON
C214
Motor 2
High threshold of inrush current control during
closing
1 – 20 [A]
20
C215
Motor 2
Low threshold of inrush current control during
closing
1 – 19 [A]
19