ProCon GSM
•
The Reading and Sending buttons at the bottom are for readout and edit of the module configuration. These
buttons are accessible everywhere except on the Controlling phone numbers tab.
You should send data to the module with the Send button after every significant modification.
Before sending your settings make sure those will not trigger an unexpected alert. You should readout the
actual module state beforehand (Maintenance tab).
WARNING! After connection always readout the settings first if you would like to alter those.
•
You can restart the module with the Restart button. After monitoring is complete the module should
be restarted.
•
In the lower menu line you can be informed of the followings:
◦
Communication port number
◦
GSM module name
◦
Firmware version number
◦
Notification on the actual software process
◦
ProRead version number
Checking module status
You can reach the actual status through Maintenance
→
Show module status button
By the module status query you will be informed of the followings:
•
input statuses
•
output statuses
•
Tamper sabotage notification
•
power supply failure notification
•
armed/disarmed module status
•
displaying occurring error/event codes (ex.: no SIM card inserted, SIM card locked by PIN code)
•
checking Contact ID code (to monitoring station) sending process (ex. handshake status)
•
GSM connection status (ex. connected to the network, roaming, no connection, connection rejected)
•
actual GSM signal strength (refreshing in seconds)
Switching off PIN code request on SIM card
Before inserting SIM card in the module the PIN code request should
be switched off
•
If you have not done yet then you can switch off at
Maintenance
→
Switch off PIN code request.
•
You will see the following window, where you can input the code
and its request will be switched off.
Page 9
Содержание ProCon GSM
Страница 1: ...ProCon GSM PROFESSIONAL GSM GPRS TRANSMITTER INSTALLATIONAL AND USER S GUIDE Version 2 1 ...
Страница 12: ......