ProCon GSM
Programming with SMS commands
Module can also be programmed by SMS commands. SMS starts always with the security code that can be modified
whenever you want. Commands can be piled but the SMS length must be under 160 characters.
The module (if it is possible) will send reply SMS after every message. You can switch this off with NO SMS command or
with the RECALL command when the module makes a call to confirm the successful programming.
Command criteria:
•
can not contain accented characters
•
command characters are capitals
•
commands have to be separated with space
•
besides = you can also use #.
•
messages have to start with security code that is followed by first command without space
•
SMS text command has to end with # character
Command List:
Description
SMS
command
x value
value after = sign
Example
editing SMS security code
CODE
= new security code
1234CODE=4321
adjust clock
CLOCK
= yymmddhhmm
yy: year, mm: month
dd: day, hh: hour
mm: minute
1234CLOCK=1401200922
Date will be: 2014.01.20 09:22
save telephone number for caller
identification
ADD
= telephone number (with +36)
136305551234
removing telephone number from
caller number identification list
DEL
= telephone number (with +36)
136305551234
saving/editing telephone number
for notification
TEL
x
telephone ordinal
number from 1 to 8
= telephone number (with +36)
1236305551234
input setup
INPUT
x
input ordinal number
= tnneeeeeeee
t:0
→
switched off, 1
→
24 h
normal, 2→ backup; 3→
normal alarm 4
→
delayed
alarm
nn
→
NO or NC
eeeee..: Other parameters:
1.e=1
→
send SMS of status
revertion
2.e=0
→
compulsory 0
3.e=1
→
siren sound
4.e=1
→
voice message
5.e=1
→
remote surveillance
6.e=1
→
no need to pickup
when calling
7.e=1
→
DTMF confirmation
(#)
8.e=0
→
compulsory 0
1234INPUT1=INC00100000
First input is:
-24 h normal
-Normal Close
- not sending SMS when reverts
back to initial state
- plays siren sound when calling
- no voice message
- no remote surveillance
notification
- when calling must be picked up
-no need for DTMF confirmation
Output setting
OUTCONF
x
output serial
= iiiiirhn
iiii
→
if 00000 then it will be
bistable, otherwise it is the
duration of control in seconds
r
→
controlled when alarm
h
→
controlled when call
n
→
=1
→
without caller
identification
1234OUTCONF=00003110
output is in 3 seconds
monostable mode, it can be
controlled by call and alarm and
number identification is a must
during a call
Life sign sending
LIFETEST
= cccsstttttttt
ccc
→
cycle time, how often to
send message (ex.:030
days)
ss
→
on the given day at what
time (ex.: at 12 o’clock)
tttttttt
→
which telephone
number to choose from the 8
ex.: 00100000
→
3
rd
phone
number, 01010000
→
2
nd
and
4
th
etc.)
1234LIFETEST=0071100100100
-in 7 days
-at 11 a.m.
-sending to 3
rd
and 6
th
telephone
number
Page 20