ProCon GSM
GSM gate control compact view
Similar to the entryphone compact view GSM gate control settings have their separate interface. The new interface
contains every significant function for establishing a GSM based gate control system.
To activate the interface on the Connection window the Gate control compact view checkbox has to be marked
The new interface contains:
•
output (gates) configuration: monostable (timed) or bistable (two stated) controlling
•
controlling with caller identification, assigning phone numbers to gates and direct DTMF control
•
SMS and PC security code
•
firmware update
•
switch off PIN code request of the SIM card
•
event log, GSM signal strength and showing actual GSM module status
•
wiring diagrams
For GSM gate control programming you have to complete only 4 (+1) steps:
First step: set up the outputs.
•
You can freely change the output settings
•
Controlling can be monostable (one stated) or bistable (two stated)
•
At monostable operation controlling time period can be even 65,000 seconds
•
Controlling can be made with caller number identification or without identification
from unlimited telephone numbers
•
By using the Test button you can try the current settings. To use the 2nd, 3rd and
4th output an output expander (EXP Relay or EXP Relay3) is needed
Second step: save the controlling phone numbers
•
You can store up to 1,000 phone numbers in the module memory
•
phone number must comply with the international format (+ followed by country code)
•
By selecting the controlling phone number you can choose which output should be
controlled with that number
•
To control the module you just have to ring it. If you switch on direct DTMS control
module will accept your call and you can control the outputs with the buttons of your cell
phone
Third step: mind the security of your device
•
Change the SMS security code and (optionally) set your PC
programming code. Default SMS security code is 1234.
Fourth step (optional): other settings
•
By clicking the Other settings button you can set GSM module related notification possibilities
•
notification of power failure and its restoration can be sent
•
you can set life sign sending so the device will send SMS of its seamless operation
•
messages arriving to the device can be even forwarded to your phone
The final 5th step is to send settings to the GSM device