ProCon GSM
You can set on this tab if there is an alarm event caused by short or open circuit on an input to which phone number you
would like to send SMS or voice message notification. It is possible to send both notifications to the same phone number.
•
On the Input type tab you can set how the input should operate:
◦
00/Not used: not used inputs can be switched off so no jamming signals can be received.
◦
01/24h normal input: 24/7, constant, input indifferent to activation status
◦
(02/Backup: not used input left on so it can be used later)
◦
03/Center input: this input will send alert only if the module is activated.
◦
04/delayed center input: in activated state this input starts a countdown (can be set on the “Other” tab) while
you have the chance to deactivate it.
◦
05/Arming/disarming: input for arming or disarming the module. This can be controlled only with continuous
contact (ex key switch). Normally closed state is suggested so wire cutting will trigger an alarm.
•
The input can be set to be normally opened (NO) or normally closed (NC).
•
An SMS message can be sent if the input reverts back to its normal state.
•
If siren sound is selected as alarm sound voice call duration will be 25 seconds. If also the voice message option
is selected its length will be 5 seconds.
•
At voice message transmission prerecorded or custom sound can be chosen to send with a voice call (Sounds
tab)
•
Monitoring station can also be notified of the input state change.
•
You can set a no pickup mode so module will not try to call again if the call was received regardless it was
accepted or rejected.
•
When DTMF confirmation is selected it is not enough to receive the call, it has to be confirmed with the ‘’#’’ button
of the mobile phone. By pressing the ‘’*’’ button multiple calls can be even stopped.
•
The first input can be set to send notification if module is powered on. Thus the module indifferent to its state will
initiate an alarm event. This function is suggested when you want the module power-on to initiate an alarm event.
•
In the SMS message box you can set the message that can be maximum 32 characters long.
•
Input modifications can be achieved by SMS commands with the following parameters:
•
1234INPUT1=tnneeeeeeee
•
t: 0
→
switched off 1
→
24h normal 2
→
backup 3
→
alarm normal 4
→
alarm delayed nn
→
NO or NC eeeeeeee:
Other parameters: 1.e=1
→
Message of reverting back 2.3=0
→
Compulsory 0 3.e =1
→
siren sound 4.e=1
→
Voice message 5.e=1
→
Monitoring station 6.e=1
→
no need to pickup at call 7.e=1
→
DTMF acknowledge (#)
8.e=0
→
Compulsory 0
•
You can find additional information on SMS commands on page 20.
Voice message settings
In the Sounds menu a specific alert can be associated with a prerecorded voice message.
•
The function of the identifying message is to identify the module (ex. address, building name) if you are waiting
messages from several modules.
•
If you click the red record button you can record your own voice with a microphone attached to your PC. This
can be up to 8 seconds in length or 15 seconds for the identifying message.