Application Information
Video Session Application
195
PRISM MPI2-10-MPX2-10 User Manual
means that the C Channel embedded checksum value does not match the
calculated checksum value, which indicates that a transmission error has occurred.
The CRC Status display is also divided into four columns:
•
Status: Shows the status of the associated error:
– OK: No error is currently detected.
– Invalid: The data for the item is currently invalid.
– Missing: The data for the item is currently missing.
– Error: The associated error is currently in an error state.
•
Err Fields: The number of fields, since the last reset, that contained at least one
error.
•
Err Secs: The number of seconds, since the last reset, that contained at least one
error.
•
% Err Fields: Shows a calculated number showing the percentage of all fields since
the last reset that contained at least one error.