Configure the Instrument
Configure Instrument for HDR/WCG Monitoring
PRISM MPI2-10-MPX2-10 User Manual
102
The NMOS/SDP and API allows system integrators to build an IP system with PRISM
being managed by system management software. The software discovers, registers,
configures inputs, and selects the active input for monitoring.
To enable NMOS on your instrument:
1.
Select the
Settings
icon (
) to open the Settings menu.
2.
Select
Network
to open the Network submenu.
3.
Slide the Enable NMOS Discovery & Registration
control to Enabled or Disabled.
4.
Close the Network menu.
Note:
The Advertised Port is the physical port on the back of the instrument. The
Control selection is for the RJ-45 10/100/1000Mbps Ethernet port.
Note:
When changes are made to the control port IP address or the label of the
instrument and NMOS is being used for configuration, we recommend rebooting the
instrument to update the NMOS registration server.