Application Information
Waveform Application
PRISM MPI2-10-MPX2-10 User Manual
158
Cursors
Make precise measurements with time and voltage cursors.
1.
Select the
Cursors
button to show the time and voltage cursor options.
2.
Select the
T
button to
On
to display two time cursors.
3.
Select anywhere on the display to hide the
T
and
V
buttons.
4.
Select and drag anywhere on the T1 or T2 cursor to mark exact times in the trace.
The cursors highlight yellow when moved. The timestamp of each cursor and the
delta are displayed on the right side of the application.
Note:
The cursor tab provides an easy way to adjust each cursor.
5.
Change the
V
button to
On
to display two voltage cursors.
6.
Select the
V Units
button to change the voltage units between percentage (%),
millivolts (mv), or code value (CV).
7.
Select anywhere on the display to hide the buttons.
8.
Select, hold, and drag anywhere on the V1 or V2 cursor to mark exact times in the
trace. The cursors highlight yellow when moved. The voltage measurement at each
cursor and the delta are displayed on the right side of the application.
Note:
The time and voltage cursor positions are retained if the trace is moved
horizontally or vertically, or if the gain is adjusted.
Содержание PRISM MPI2-10
Страница 1: ...PRISM MPI2 10 and MPX2 10 SDI IP Waveform Monitor User Manual April 2021 D00010021C...
Страница 6: ...6 PRISM MPI2 10 MPX2 10 User Manual...
Страница 52: ...Getting Started Activity Center PRISM MPI2 10 MPX2 10 User Manual 54...
Страница 74: ...Methods of Operation Remote Control through API Commands PRISM MPI2 10 MPX2 10 User Manual 76...
Страница 302: ...PTP Operational Overview Compensating for Causes of Asymmetric Delay PRISM MPI2 10 MPX2 10 User Manual 304...