![Teleste BRILLANTE Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/teleste/brillante/brillante_user-manual_1082207020.webp)
BRILLANTE User Manual, 59300023, rev005
Configuring the BRILLANTE
•
19
Private_data_bytes CA specific data can be defined here. If
doesn’t exist the value shall be ‘-‘.
Section_Name
User defined name of a CA section. If
same name exists more than once then
new descriptors are added to already
existing CA section.
version
The version number of the entire
conditional access table.
Usable range:
1…32
.
current_next
Valid values are 0 and 1. When set to ‘1’
indicates that the Conditional Access
Table sent is currently applicable. When
set to ‘0’, it indicates that the table sent is
not yet applicable and shall be the next
CAT to become valid.
Descriptor(s)
Define the CA descriptor to be included
in corresponding CA section. The
descriptor has to be defined in
<CA_DESC> section otherwise an error
will be reported. Multiple descriptors can
be defined separated with the tabulator.
Server Name
Name of the server where the data will be
sent. This name has to be defined in
<SERVER_LIST> section otherwise an
error will be reported.
repetition_rate
Represents the period in milliseconds for
the repetition of data.
Valid range:
1000…30000.
Data_ID
16-bit identifier which uniquely identifies
a private data stream of a given client id.
This value is allocated by the user.
Data_Stream_ID
16-bit identifier which uniquely identifies
a private data stream within a channel.
This value is allocated by the user.
CA_section(s) Define
the
CA
section to be included in
corresponding CA table. The section has
to be defined in <CA_SECTION>
section otherwise an error will be
reported. Multiple sections can be
defined separated with the tabulator.
<CA_SECTION>
<CAT>