3700 Portable Samplers
Section 3 Programming Guidelines
3-11
Table 3-1 Configure Option Functions
Configure Option
Programming Mode Function
Set Clock
Basic & Extended
Sets the sampler’s real-time clock.
Bottles and Sizes
Basic & Extended
Sets the sampler for Portable or Compact configuration. Sets the
number and size of bottles used in the tub or inner sleeve.
Suction Line
Basic & Extended
Sets the type of line (vinyl or TEFLON), line diameter (
1
/
4
or
3
/
8
inch), and line length (3 to 99 feet).
Liquid Detector
Basic & Extended
Enables/disables liquid detector, sets the number of rinse cycles (0
to 3), enables/disables the suction-head entry, and sets the number
of sampling retries (0 to 3).
Programming Mode
Basic & Extended
Sets the programming mode: basic or extended.
Load Stored
Program
Extended
Loads one of as many as three previously saved sampling pro-
grams.
Save Current
Program
Extended
Saves current sampling program.
Flow-Mode
Sampling
Extended
Directs sampler to take a sample at the beginning of a flow-paced
program. Directs sampler to sample at time-switches.
Nonuniform Time
Extended
Directs sampler to accept nonuniform intervals as specific clock
times or in minutes.
Calibrate Sampler
Basic & Extended
Enables/disables the calibration sequence.
Sampling
Stop/Resume
Extended
Enables/disables Sampling Stops and Resumes feature.
Start-Time Delay
Basic & Extended
Sets the start time delay (from 0 to 9999 minutes). If no specific
start time is entered in the program sequence, the program uses the
entered start-time delay. The delay is the amount of time that will
elapse after you press the start sampling key or after the sampler is
enabled.
Enable Pin
Basic & Extended
Directs the sampler to take a sample when disabled and/or enabled
by a Liquid Level Actuator or other Isco Flow-monitoring equipment.
Allows you to restart the sampling interval when the sampler is
enabled.
Event Mark
Basic & Extended
Allows you to select one of four types of event marks.
Purge Counts
Basic & Extended
Adjusts the number of pre- and post-sample purge counts.
Tubing Life
Basic & Extended
Displays the pump tubing life information. Resets the tubing life
count.
Program Lock
Basic & Extended
Enables/disables the password protection for input displays.
Sampler ID
Basic & Extended
Allows you to enter a 10-character ID number for the sampler.
Run Diagnostics
Basic & Extended
Tests the RAM, ROM, pump, and distributor. Allows for reinitializa-
tion of certain program and configure settings.
Содержание 3700
Страница 2: ......
Страница 4: ......
Страница 33: ...3700 Portable Samplers Section 2 Setup Procedures 2 9 Figure 2 7 Locked Sampler ...
Страница 34: ...3700 Portable Samplers Section 2 Setup Procedures 2 10 ...
Страница 99: ...3700 Portable Samplers Section 3 Programming Guidelines 3 65 Figure 3 14 Start Time Diagram I I I I I I ...
Страница 144: ...3700 Portable Samplers Section 3 Programming Guidelines 3 110 ...
Страница 152: ...3700 Portable Samplers Section 4 Options and Interfacing Equipment 4 8 ...
Страница 164: ...3700 Portable Samplers Section 5 Routine Maintenance 5 12 ...
Страница 175: ...3700 Portable Samplers Section 6 Servicing 6 11 Figure 6 6 Main Circuit Board Component Layout OUT OUT OUT OUT OUT OUT ...
Страница 180: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 2 ...
Страница 181: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 3 ...
Страница 182: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 4 ...
Страница 183: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 5 ...
Страница 184: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 6 60 3703 262 REV J 3 2 ...
Страница 186: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 8 ...
Страница 188: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 10 ...
Страница 189: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 11 ...
Страница 190: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 12 ...
Страница 191: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 13 ...
Страница 192: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 14 ...
Страница 193: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 15 ...
Страница 194: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 16 ...
Страница 195: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 17 ...
Страница 196: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 18 ...
Страница 200: ...3700 Portable Samplers Appendix B Accessories B 4 ...
Страница 210: ...3700 Portable Samplers Appendix C General Safety Procedures C 10 ...
Страница 224: ...3700 Portable Samplers Appendix E Calculating Flow Increment Between Samples E 4 ...
Страница 234: ...3700 Portable Samplers Appendix G Material Safety Data Sheets G 8 ...
Страница 238: ......
Страница 240: ......
Страница 242: ......