3700 Portable Samplers
Appendix D Display Index
D-7
Bottles and Sizes configure option. Select “PORTABLE” when you are using a 3700 Compact or Standard Sampler.
Select REFRIG only if you have a refrigerated base unit.
Display 220
[PORTABLE, REFRIG]
SAMPLER
Bottles and Sizes configure option. This display appears when you select “PORTABLE” in Display #220. Select the
number of bottles in the bottle base.
Display 221
[1, 4, 12, 24]
BOTTLES
Bottles and Sizes configure option. This display appears when you select “REFRIG” in Display #220. Select the num-
ber of bottles in the base.
Display 222
[1, 2, 4, 8, 12, 24]
BOTTLES
Bottles and Sizes configure option. Enter the bottle volume in milliliters.
Display 223
BOTTLE VOLUME IS
----- ml
Bottles and Sizes configure option. This display appears when you have entered a bottle volume in Display #223 that
exceeds a standard Teledyne Isco bottle size.
Display 224
---- ml ... ARE YOU
SURE?
[YES, NO]
Suction Line configure option. Select “
1
/
4
” if you are using
1
/
4
-inch suction line, “
3
/
8
” if you are using
3
/
8
-inch suction
line.
Display 230
SUCTION LINE ID IS
[1/4, 3/8] INCH
Suction Line configure option. This display appears when you have selected “
3
/
8
” in Display #230. Select “VINYL” if
you are using vinyl suction line, “PTFE” if you are using PTFE suction line.
Display 231
SUCTION LINE IS
[VINYL, PTFE]
Suction Line configure option. Enter the length of the suction line. Do not include the tube coupling or the strainer in
the length measurement.
Display 232
SUCTION LINE LENGTH
IS -- FEET (3 - 99)
Liquid Detector configure option. Select “ENABLE” to turn on the Liquid Detector, “DISABLE” to turn off the Liquid
Detector. If you turn off the detector, you must enter the suction head (Display #70) in the program sequence.
Display 240
[ENABLE
,
DISABLE]
LIQUID DETECTOR
Liquid Detector configure option. This display appears when you select “ENABLE” in Display #240. Enter the number
of rinse cycles. Rinse cycles condition the suction line to reduce cross-contamination.
Display 241
RINSE CYCLES (0 - 3)
Liquid Detector configure option. This display appears when you select “ENABLE” in Display #240. Select “YES” to
add the suction-head setting (Display #70) to the program sequence. Select “NO” to omit the setting.
Display 242
ENTER HEAD MANUALLY?
[YES
,
NO]
Liquid Detector configure option. This display appears when you select “ENABLE” in Display #240. Enter the number
of retries: the number of times the sampler will try to detect the presence of liquid for each sample event.
Display 243
RETRY UP TO - TIMES
WHEN SAMPLING
(
0 - 3
)
Table D-1 Display Index (Continued)
Содержание 3700
Страница 2: ......
Страница 4: ......
Страница 33: ...3700 Portable Samplers Section 2 Setup Procedures 2 9 Figure 2 7 Locked Sampler ...
Страница 34: ...3700 Portable Samplers Section 2 Setup Procedures 2 10 ...
Страница 99: ...3700 Portable Samplers Section 3 Programming Guidelines 3 65 Figure 3 14 Start Time Diagram I I I I I I ...
Страница 144: ...3700 Portable Samplers Section 3 Programming Guidelines 3 110 ...
Страница 152: ...3700 Portable Samplers Section 4 Options and Interfacing Equipment 4 8 ...
Страница 164: ...3700 Portable Samplers Section 5 Routine Maintenance 5 12 ...
Страница 175: ...3700 Portable Samplers Section 6 Servicing 6 11 Figure 6 6 Main Circuit Board Component Layout OUT OUT OUT OUT OUT OUT ...
Страница 180: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 2 ...
Страница 181: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 3 ...
Страница 182: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 4 ...
Страница 183: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 5 ...
Страница 184: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 6 60 3703 262 REV J 3 2 ...
Страница 186: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 8 ...
Страница 188: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 10 ...
Страница 189: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 11 ...
Страница 190: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 12 ...
Страница 191: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 13 ...
Страница 192: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 14 ...
Страница 193: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 15 ...
Страница 194: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 16 ...
Страница 195: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 17 ...
Страница 196: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 18 ...
Страница 200: ...3700 Portable Samplers Appendix B Accessories B 4 ...
Страница 210: ...3700 Portable Samplers Appendix C General Safety Procedures C 10 ...
Страница 224: ...3700 Portable Samplers Appendix E Calculating Flow Increment Between Samples E 4 ...
Страница 234: ...3700 Portable Samplers Appendix G Material Safety Data Sheets G 8 ...
Страница 238: ......
Страница 240: ......
Страница 242: ......