Model CFA-24 Transparent Cable Farm Automation Switch Reference Manual Page 71 of 78
set microcut <line> <location> <open time in ms> <period> <count>
Valid Values:
<line> is only a single channel number (Only single channel can be interrupted)
<location> co, cpe or both
<open time in ms> is the length of time for which the line is cut in milliseconds.
Allowable Range: 5 ms to 750 ms
Increments: 5 ms.
<period> is the time of the complete cycle. The cycle consists of the interrupt time and the closed time.
Periods are only in seconds.
Allowable Range: 1 s to 31 s
Increments: 1 s
<count> represents the number of line on/off events to execute.
Allowable Range: 1 to 255 counts
Increments: 1 count
Example
Command:
set microcut 1 co 5 1 5
Response:
CFA-24:~$set microcut 1 co 5 1 5
ACCEPTED set microcut 1 co 5 1 5
Channel(1) interrupt running
CFA-24:~$