Model CFA-24 Transparent Cable Farm Automation Switch Reference Manual Page 31 of 78
Not Used (N) Coordinate Type:
•
Any or all coordinates in a segment row may be designated as an N, even if that row has SP’s or MP’s.
•
If a row has an MP and at least one N, then all channels that have an N in that particular row may only
have an N or SP above that point (i.e., in a higher segment number).
Example of Differences in Results
Using multi-pair coordinates only on all channels and segments:
CH1-24, Segment 1: 25
CH1-24, Segment 2: 50
CH1-24, Segment 3: 100
CH1-24, Segment 4: 200
CH1-24, Segment 5: 100
Potential available line lengths: 25, 75, 175, 375, 475
Using single-pair coordinates only on all channels and segments:
CH1-24, Segment 1: 25
CH1-24, Segment 2: 50
CH1-24, Segment 3: 100
CH1-24, Segment 4: 200
CH1-24, Segment 5: 100
Potential available line lengths: 25, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300, 325, 350, 375,400, 425, 450, 475