Model CFA-24 Transparent Cable Farm Automation Switch Reference Manual Page 32 of 78
•
Select COORDINATE MATRIX from the INSTALLATION CONFIGURATION MANAGEMENT screen.
The Installation Configuration Management screen example for a standalone unit.
•
Select Coordinate Type from the dropdown field, under the “T” column for the desired coordinate. See
Considerations When Selecting Coordinate Types and Lengths
.
o
N:
Represents “Not Used.” Select
N
when no loop segment is attached to this coordinate.
o
MP:
Select
MP
(multi-pair) when the loop segment attached to this coordinate is part of the multi-pair
cable portion of the test setup. It is expected that crosstalk occurs between multi-pairs. When using
Multi-Pairs in the Coordinate Matrix, use CONFIGURE MP CABLES to set up the number of
Vectoring Groups.
o
SP:
Select
SP
(single pair) when the loop segment attached to this coordinate is used for the single-
pair portion of the test setup.
•
Enter Coordinate Length. This field is mandatory when the Coordinate Type is MP or SP. The value entered
must match the length of physical twisted multi-pair cable connected to a connector segment.
•
VG#:
Display field showing the current Vectoring Group number assigned to the channel. A blank field
indicates there is one Vectoring Group (default). If this unit is a Controller or Standalone and MP’s are
configured, select CONFIGURE MP CABLES to configure Vectoring Groups.