![Telebyte CFA-24 Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/telebyte/cfa-24/cfa-24_reference-manual_1079741078.webp)
Model CFA-24 Transparent Cable Farm Automation Switch Reference Manual Page 74 of 78
set ncl <vectoring group> <segment><checked|unchecked>
Checks or unchecks segments in one or more vectoring groups. Equivalent of checking the same segment in the “Check
to Include” column on the Test Maintenance screen.
<vectoring group> a single vectoring group or a range of vectoring groups separated by a colon (e.g., vg1:vg5)
<segment> a segment number
Allowable values: 1, 2, 3, 4 or 5
<checked|unchecked> changes the status of the segment to checked or unchecked.
Allowable values: (u)nchecked or (c)hecked.
Example
Command: set ncl vg1 1c 2c 3c 4c 5u
Response: ACCEPTED set ncl vg1