Model CFA-24 Transparent Cable Farm Automation Switch Reference Manual Page 54 of 78
Example Set Leave screen.
•
Select Interrupt:
Select the interrupt type of Microcut, Cut or Leave from the dropdown.
➢
An interrupt type of Cut, once started, can only be stopped by entering a “set interrupt off” remote
command from a second connection.
•
Select Channel to Interrupt:
using the dropdown select the one channel to which the interrupt will apply.
•
Interrupt Location:
select CO or CPE or CO & CPE (Standalone units only) from the dropdown.
•
Interrupt Time:
o
Microcuts: 5ms to 750ms
o
Cuts: 2s to 60s
•
Time Between Interrupts:
if the interruption is to be repeated, enter the number of seconds in-between each
interruption event (e.g., 1s to 31s for a micro-interruption).
•
Total Interrupt Sequence Count:
repeat the sequence until this length of time is reached.
•
Save:
click the Save button to begin the interruption. The progress bar is shown.
•
When the sequence is complete, the Interrupt screen is shown.