Specifications
2--6
TMSST1 775-Pin Socket Hardware Support
Table 2--3: Environmental specifications (cont.)
Characteristic
1
Description
Electrostatic immunity
The probe adapter is static sensitive
Required airflow clearances
for the preprocessor unit
Front, top, left side
5.08 cm (2 in)
Back
7.62 cm (3 in)
Bottom, right side
0.635 cm (0.250 in)
1
Designed to meet Tektronix standard 062-2847-00 class 5.
2
Not to exceed Microprocessor thermal considerations. Customer supplied cooling
might be required across the CPU.
Table 2--4: Certifications and compliances
Category
Standards or description
EC Declaration of Conformity --
Low Voltage
Compliance was demonstrated to the following specification as listed in the Official Journal of the
European Communities:
g
Essential requirements of the Low Voltage Directive 73/23/EEC, amended by 93/68/EEC
U.S. Nationally Recognized
Testing Laboratory Listing
UL61010B:2003
Standard for electrical measuring and test equipment.
Canadian Certification
CAN/CSA C22.2 No. 1010.1
Safety requirements for electrical equipment for measurement,
control, and laboratory use.
Additional Compliance
IEC61010--1/A2:1995
Safety requirements for electrical equipment for measurement,
control, and laboratory use
Installation (Overvoltage)
Category Descriptions
Terminals on this product may have different installation (overvoltage) category designations. The
installation categories are:
g y
p
CAT III
Distribution-level mains (usually permanently connected). Equipment at this level is
typically in a fixed industrial location.
CAT II
Local-level mains (wall sockets). Equipment at this level includes appliances, portable
tools, and similar products. Equipment is usually cord-connected.
CAT I
Secondary (signal level) or battery operated circuits of electronic equipment.
Equipment Type
Test and measuring
Safety Class
Class 1 (as defined in IEC 61010-1, Annex H) -- grounded product
Overvoltage Category
Mains input: Overvoltage Category II (as defined in IEC 61010-1, Annex J)
All other inputs and outputs: 5 V maximum
Pollution Degree
Pollution Degree 2 (as defined in IEC 61010-1). Note: Rated for indoor use only.
Содержание TMSST1
Страница 1: ...Instruction Manual TMSST1 775 Pin Socket Hardware Support 071 1315 00 www tektronix com ...
Страница 4: ......
Страница 8: ...Table of Contents iv TMSST1 775 Pin Socket Hardware Support ...
Страница 12: ...Service Safety Summary viii TMSST1 775 Pin Socket Hardware Support ...
Страница 15: ...Getting Started ...
Страница 16: ......
Страница 35: ...Specifications ...
Страница 36: ......
Страница 45: ...Reference ...
Страница 46: ......
Страница 49: ...Replaceable Parts List ...
Страница 50: ......
Страница 56: ...Replaceable Parts List 4 6 TMSST1 775 Pin Socket Hardware Support ...
Страница 57: ...Index ...
Страница 58: ......