![Tektronix TLA 700 Series Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/tektronix/tla-700-series/tla-700-series_installation-manual_1078203067.webp)
Restoring and Reinstalling Software
50
TLA700 Series Logic Analyzer Installation Manual
Complete the following steps to upgrade the module firmware on the TLA7Lx,
TLA7Mx, TLA7Nx, TLA7Px, or TLA7Qx logic analyzer modules and the
TLA7Dx or TLA7Ex oscilloscope modules. These modules require you to install
a jumper on the rear of the module before you can upgrade the firmware.
1.
Note which of the modules that may require new firmware.
If any modules are missing from the System window, you can verify the
status of the modules by doing the following steps:
a.
Select System Properties in the System menu.
b.
Click the Modules tab.
c.
Note the information under the Messages column for any installed
modules. If any modules indicate invalid or similar messages, you must
update the firmware for those modules.
2.
Turn off the logic analyzer and disconnect the power cord.
3.
Remove the modules from the logic analyzer.
4.
Refer to Figure 28 on page 51 and locate the flash programming pins on the
rear of each module.
5.
Install a jumper on the flash programming pins (use one of the spare jumpers
that came with your logic analyzer).
6.
Reinstall the module(s) in the logic analyzer.
7.
Reconnect the power cord and then power on the logic analyzer.
8.
Wait for the TLA application to start.
NOTE
. Any modules with the flash programming jumper installed will not display
in the System window.
9.
Exit the TLA application (and pattern generator application if you have it
installed on your instrument).
Upgrading Firmware on
TLA7Lx/Mx/Nx/Px/Qx/
Dx/7Ex Modules