Merging TLA700 Modules
TLA700 Series Logic Analyzer Installation Manual
37
The following procedure is used for merging three logic analyzer modules
together to form a merged set with a higher logic analyzer channel count.
In a three-way merge (TLA7Nx, TLA7Px, and TLA7Qx logic analyzer modules
only), the master module is in the center. Slave module 1 is to the right of the
master module. Slave module 2 is on the left of the master module as shown in
Figure 17 on page 27.
CAUTION.
Static discharge can damage any semiconductor component in the
logic analyzer module.
Discharge the static voltage from your body by wearing a grounded antistatic
wrist strap while performing the merge procedure.
Perform the
Two-Way Logic Analyzer Merge Procedure
beginning on page 32.
Perform the following steps to merge the second slave module:
1.
Lay the two merged module set on its right side (as viewed from the front
panel).
2.
Follow the procedure beginning on page 32 to merge the second slave
module to the left of the center master module.
Perform the following steps to store the logic analyzer merge cable inside the
logic analyzer module:
1.
Use the screwdriver with the T-10 Torx tip to remove the screws that hold
the merge cable bracket in place.
2.
Remove the merge cable bracket.
3.
Remove the screws from the side cover and rear cover.
4.
Push the merge cable through the side cover and remove the cover.
5.
Position the merge cable as shown in Figure 25.
Three-Way Logic Analyzer
Merge Procedure
Storing the Logic Analyzer
Module Merge Cable