![Tektronix PFG 5105 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/tektronix/pfg-5105/pfg-5105_instruction-manual_1077779042.webp)
(
(
(
VCO/FM
INPUT
-7 to +7
Volt range
Operating Instructions
Limited to
0 to 7
/�
0 to 7
Volt range
Volt range
ru
�
-,--
uP
Frequency
'\
vco
Control
>
· Triangle
/V
/
DAC
Generator
',______,/
�
Fig. 2-6. Triangle generator architecture.
External VCO Example:
To get a swept output from approximately 1 to 5 kHz:
• Set Frequency to 11 kHz.
• Set Range Lock ON and FM mode ON.
• Set a ramp generator to start a 1 V and end at
3 V.
This setup will provide a linear sweep of output
frequency from about 1 kHz to 5 kHz.
Frequency Lock.
With frequency lock on, internal
circuitry improves the generator's frequency accuracy.
For operation to specified frequency accuracy, fre
quency lock should be on. The default setting is
frequency lock on. Frequency lock is disabled when
FM mode is selected. Frequency lock can be turned
off by using a SPCL function. Refer to Special Func
tions in this section of the manual.
Amplitude Modulation
A signal applied to the AM IN connector modulates
the amplitude of the output waveform. Amplitude
NORMAL MODULATION
0.6 V Modulating Signal
modulation effectively multiplies the amplitudes of the
generator and the external signal applied to the AM
IN connector.
A modulating signal of approximately 4.5 volts peak
to-peak will cause 1 GO-percent modulation of the
output if the output amplitude is set to 5 V peak-to
peak; if the output amplitude is greater than 5 V
peak-to-peak, a 4.5 V modulating signal will cause
clipping of the output signal. Refer to Table
1 -1 0,
AM
INPUT, in the Specifications section.
The PFG 5105/5505 output amplifier cuts off at
=::
10.2
volts peak to peak. Any modulation that causes a
peak-to-peak voltage near this limit will distort the
output. The maximum output voltage that can have
100% modulation is 5.1 volts peak to peak.
See Fig 2-7 for an example of how an output of g
volts peak-to-peak is distorted with a 0.8 volt modulat
ing signal but not with a 0.6 volt modulating signal.
To enable amplitude modulation, press the AM key
(LED on).
DISTORTED MODULATION
0.8 V Modulating Signal
Fig. 2-7. AM Distortion.
PFG 5105/5505 Instruction Manual
2-1 5
Содержание PFG 5105
Страница 1: ...PFG 5105 PF G 5505 Programmable Pulse Function Generator...
Страница 9: ...i I...
Страница 27: ......
Страница 87: ......
Страница 89: ......