Figure 6 - Double Patient Station Default Room (Address 0-29)
Figure 7 - Duty Station Default Room Controller Points (Address 30-31)
Tek-CARE120 Station Wiring
When installing wiring to stations, use 18-22 AWG cable. Do not exceed 100 feet of cabling for SF121,
SF122, and SF123 stations. For SF125 stations, do not exceed 50 feet of cabling. Only one station may
be connected to each point. Do not splice multiple stations together on the same point wiring.
One-to-One Installations
In most installations, one room controller will be used as a connection point for all of the stations in the
associated room. This provides the simplest software configuration option, but other installation
strategies are available.
In a one-to-one installation, connect the stations to the room controller according to the table on the pre-
vious page.
16
|
IL992 Tek-CARE120 Installation Manual