machine perimeter. Guards must be used only to limit personnel
access to hazards within the machine.
11.
The human possibility of avoidance or limiting harm (e.g. reflex,
agility, possibility of escape) for all hazards associated with this
machine can be impossible. (EN 1050 7.2.3.3)
12.
Hazards in this machine are to a person or several persons and
where the highest consequence may be serious (non-reversible)
injury or death. (EN 1050 7.2.2)
13.
The E-Stop switches, interlocks with and without guard-locking
and any external power disconnect contactors must meet the
required standards :
EN 418
E-Stop equipment, functional
aspects
EN 60947-5-1
E-Stop and interlock switch contact
block requirements
EN 60947-5-5
E-Stop actuator requirements
EN 1088
Interlocking devices for guards
EN 60947-4-1
Electromechanical contactors
14.
The E-Stop switch (or switches) must be placed where they are
readily accessible by machine operators as per EN 292-2 Section
3.6.
15.
Power to devices from circuits connected to J
A
and J
B
and pins 6
& 9 on J5 must be protected from being touched by personnel,
i.e. these circuits are not accessible (as per EN 61010-1) within
the machine. These devices must require that a tool is used to
access any hazardous circuits or hazardous mechanical elements.
The cables which supply power to devices within the machine
from J
A
and J
B
and pins 6 & 9 on J5 should be clearly marked
with the shock hazard international symbol. There should be
marking on cables and components powered from this power
source, which states that the circuit is live and not interrupted by
safety interlock. An example of acceptable marking is shown
below.
Example label
16.
Hazards that might exist in a machine, but that are not rendered
safe when electrical power is removed may include, but are not
limited to: chemical hazards, nuclear radiation, potential energy
(from springs, elevated loads, pressurized fluids and/or
pressurized gases), explosive materials, sharp edges, impalement
hazards, etc. are beyond the scope of this document. These
hazards can likely be controlled and monitored by a safety
control system based upon the eF-785, however, no attempt has
been made to consider them herein.
17.
The machine must pass (or be able to pass) EN61010-1.
18.
All accessible metal parts must be bonded to protective earth.
e F - 7 8 5
I
N S T A L L A T I O N
M
A N U A L
61
T
EKNIC
,
I
NC
F
AX
(585)784-7460
V
OICE
(585)784-7454
Содержание EF-785
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Страница 67: ...48 90VDC MAIN AREA TO SST P7A P7B eF 785 INSTALLATION MANUAL 65 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Страница 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Страница 71: ...AC SERVO POWER CABLE MAIN AREA P3 eF 785 INSTALLATION MANUAL 69 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Страница 73: ...SST 6000 3000 AC INPUT CABLE eF 785 INSTALLATION MANUAL 71 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Страница 75: ...DUAL 24VDC SUPPLY CABLE J5 eF 785 INSTALLATION MANUAL 73 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Страница 77: ...24VDC DIST CABLE IOC APC P9 P11 eF 785 INSTALLATION MANUAL 75 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Страница 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Страница 81: ...EXTENSION CHEATER PLUG P13 eF 785 INSTALLATION MANUAL 79 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...