P
OWER
-
OFF
-
DELAY
O
PTIONS
(L
OAD
)
The power-off-delay in the Load Area is configured in the same way as
described in the Main Area. If there is no Load Area select code
X
in the
F-785 part number where indicated.
N
No
delay required
F
Fast
delay (150 mS) - For smaller axes or axes where high rates of
deceleration are tolerable.
S
Slow
Delay (450mS) - For larger axes or axes where more testtime is
required.
X
Not applicable. No Load Area designated.
S
UPPLEMENTARY
O
PTIONS
C
ONFIGURING
S
UPPLEMENTARY
O
PTIONS
The Soft Shutdown and Post E-Stop Enable features comprise the eF-785
Supplementary Options. Each of these two options is factory
preconfigured to your specification, but can be reconfigured by
repositioning one or two hardware jumpers. Below is a list of the 4
possible Supplementary Option configurations available with the eF-785.
B
Host Soft Shutdown disabled; Post E-Stop Enable bypassed
C
Host Soft Shutdown enabled; Post E-Stop Enable bypassed
D
Host Soft Shutdown disabled; Post E-Stop Enable required
E
Host Soft Shutdown enabled; Post E-Stop Enable required
S
OFT
S
HUTDOWN
F
EATURE
The soft shutdown feature allows you to power off your machine by
shutting down the host computer. This feature is user configurable by
installing (or removing) an internal hardware jumper. See the appendix
for details.
Example scenario of a system with Soft Shutdown enabled:
Power up with Soft Shutdown enabled
- An operator initiates the
machine power-up cycle by pressing the machine’s front panel “on”
button (which is wired into the eF-785). The machine powers up and the
eF-785 sends AC power to the host computer which then powers up as
well. Immediately, the PC sends a signal, via USB connection, to the
eF-785, creating a feedback loop. And, as long as the USB signal is
present at the eF-785’s USB port, the system remains powered. Note: to
use this feature, the BIOS on the control PC must be configured to power
up the PC when AC power is detected.
e F - 7 8 5
I
N S T A L L A T I O N
M
A N U A L
17
T
EKNIC
,
I
NC
F
AX
(585)784-7460
V
OICE
(585)784-7454
Содержание EF-785
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Страница 67: ...48 90VDC MAIN AREA TO SST P7A P7B eF 785 INSTALLATION MANUAL 65 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Страница 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Страница 71: ...AC SERVO POWER CABLE MAIN AREA P3 eF 785 INSTALLATION MANUAL 69 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Страница 73: ...SST 6000 3000 AC INPUT CABLE eF 785 INSTALLATION MANUAL 71 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Страница 75: ...DUAL 24VDC SUPPLY CABLE J5 eF 785 INSTALLATION MANUAL 73 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Страница 77: ...24VDC DIST CABLE IOC APC P9 P11 eF 785 INSTALLATION MANUAL 75 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Страница 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Страница 81: ...EXTENSION CHEATER PLUG P13 eF 785 INSTALLATION MANUAL 79 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...