DC Motor Supply
48-90VDC
P6
1
2
3
4
5
6
7
8
9
1
2
9
8
7
6
5
4
3
Main hazard power - line
Main hazard power - neutral
Protective earth
DC motor power return
DC motor power return
no connection
DC motor power +
DC motor power +
no connection
Pin # Signal
DC motor supply connector P6
Any connected DC motor supply should have an internal fuse or other
current limiting device to protect against catastrophic failure of the
supply itself. The negative (return) lead of the power supply should
not
be connected to safety ground at the power supply. This connection is
made internally in the eF-785, and to avoid any ground loops, should not
be done externally.
P6
1
AC Line (1)
2
AC Line (2)
Safety Gnd
3
4
5
6
7
8
EF-785
DC Power Supply
Return (V+)
Return (V+)
N/C
9
+V
+V
N/C
Connecting a DC power supply for the 48-90V motor
drives
The connector that mates to P6 is a Tyco Electronics (AMP) MATE-N-
LOK™ Style connector part number 1-480706-0 and female crimp
sockets part number 350550-3.
C
ONNECTING THE
L
OADS
(DC
M
OTOR
D
RIVES
)
(P7A,
P7B,
J8A,
J8B)
The eF-785 can manage power for any DC powered stepper or servo drive
from 48VDC up to 90VDC. The DC motor power is split into two
separately switched circuits (referred to as Main and Load) and is
protected with time-delay fuses located on the eF-785 front panel. Each
circuit is separately fused at 15A maximum (F6 and F7) yielding a total of
30A available for DC motor power. Each fuse has a dedicated blown fuse
indicator LED on the eF-785 front panel.
e F - 7 8 5
I
N S T A L L A T I O N
M
A N U A L
31
T
EKNIC
,
I
NC
F
AX
(585)784-7460
V
OICE
(585)784-7454
Содержание EF-785
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Страница 67: ...48 90VDC MAIN AREA TO SST P7A P7B eF 785 INSTALLATION MANUAL 65 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Страница 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Страница 71: ...AC SERVO POWER CABLE MAIN AREA P3 eF 785 INSTALLATION MANUAL 69 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Страница 73: ...SST 6000 3000 AC INPUT CABLE eF 785 INSTALLATION MANUAL 71 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Страница 75: ...DUAL 24VDC SUPPLY CABLE J5 eF 785 INSTALLATION MANUAL 73 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Страница 77: ...24VDC DIST CABLE IOC APC P9 P11 eF 785 INSTALLATION MANUAL 75 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Страница 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Страница 81: ...EXTENSION CHEATER PLUG P13 eF 785 INSTALLATION MANUAL 79 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...