S
TEP
3:
M
OUNT THE E
F-785
This section describes how to properly mount the eF-785 to your
machine. It includes the unit’s physical dimensions, mounting hole
specifications, minimum clearances, and recommended spatial
orientations.
I
MPORTANT
M
OUNTING
D
IMENSIONS
3.0
16.85
18.00
19.00
18.25
3.47
3.00
8-32 MTG HOLE
6 PLA
CES
IMPOR
T
ANT
:
ALLO
W 3" MINIMUM
REAR CLEARANCE
F6
24
VDC
Ckt. 3
10A Max.
40
VDC
ControlPoint
TM
24
VDC
Safety
F7
F8
F10
F9
DC Servo Main
15A Max.
DC Servo Option
15A Max.
CB2
CB3
Status
24
VDC
Ckt. 2
10A Max.
24
VDC
Ckt. 1
10A Max.
SAFETY ALARM
Do not operate or service
machine if sounding
eFoundation- Power Distribution & Safety Control Center
CB1, UL489 Rated Input Breaker
10,000A Interrupting
When installed according to the
accompanying instructions this unit meets:
- UL 508
- EN 61010
- EN 60204
- EN 954-1 (Class 2)
- Semi S2
- EN 50081-2
- EN 50082-2
Teknic, Inc.
F
e
785
20
20
EF-785 physical dimensions and mounting specifications
e F - 7 8 5
I
N S T A L L A T I O N
M
A N U A L
21
T
EKNIC
,
I
NC
F
AX
(585)784-7460
V
OICE
(585)784-7454
Содержание EF-785
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Страница 67: ...48 90VDC MAIN AREA TO SST P7A P7B eF 785 INSTALLATION MANUAL 65 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Страница 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Страница 71: ...AC SERVO POWER CABLE MAIN AREA P3 eF 785 INSTALLATION MANUAL 69 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Страница 73: ...SST 6000 3000 AC INPUT CABLE eF 785 INSTALLATION MANUAL 71 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Страница 75: ...DUAL 24VDC SUPPLY CABLE J5 eF 785 INSTALLATION MANUAL 73 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Страница 77: ...24VDC DIST CABLE IOC APC P9 P11 eF 785 INSTALLATION MANUAL 75 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Страница 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Страница 81: ...EXTENSION CHEATER PLUG P13 eF 785 INSTALLATION MANUAL 79 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...