J5
1
2
3
4
5
6
7
8
9
1
2
9
8
7
6
5
4
3
Main AC Hazard Power - line
Main AC Hazard Power - neutral
Protective earth
24VDC return (Ckts 2 and 3)
+24VDC (Ckts 2 and 3)
AC Control Power - line
24VDC return (Ckt 1)
+24VDC (Ckt 1)
AC Control Power - neutral
Pin # Signal
24VDC
Supplies
J5 24VDC power supply connector
AC
C
ONTROL
P
OWER
We refer to the first “type” of AC power as AC Control Power. This simply
means that AC line voltage is always available at the 24VDC supply
connector when machine power is on, regardless of the state of the E-
stop or interlock switches. AC Control Power is typically used to supply a
24VDC supply that will be powering sensors and non-hazardous
actuators throughout the machine. This type of power will remain on
even after a safety event (E-Stop) in the machine has occurred.
M
AIN
AC
(H
AZARD
)
P
OWER
We refer to the second “type” of AC power available to an external 24VDC
supply as Main AC Power. This means that power to the 24VDC supplies
is on only when hazardous power in the Main area of the machine is on.
Main AC Power is removed after a safety event (E-Stop) has occurred.
Although 24V is not considered hazardous (when fused at or below 10A),
it is often desirable to have some or all of it turn off when a safety event
occurs e.g. in order to turn off solenoid valves such that pneumatics will
exhaust to release pressure in mechanisms, for removing power to low
power stepper motor drives
2
, etc.
There are four 24VDC wiring configurations available depending on
your project requirements. Please refer to the following schematic
fragments for details.
2 Note that although the eF-785 can remove AC power to externally connected 24VDC
supplies, it does not provide any means for quick-discharge of the connected supplies
once AC power is removed. This is usually not an issue if a switching supply is used for
the 24V, which is common, the 24VDC will usually drop very quickly, in less than a few
hundred milliseconds.
e F - 7 8 5
I
N S T A L L A T I O N
M
A N U A L
25
T
EKNIC
,
I
NC
F
AX
(585)784-7460
V
OICE
(585)784-7454
Содержание EF-785
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Страница 67: ...48 90VDC MAIN AREA TO SST P7A P7B eF 785 INSTALLATION MANUAL 65 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Страница 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Страница 71: ...AC SERVO POWER CABLE MAIN AREA P3 eF 785 INSTALLATION MANUAL 69 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Страница 73: ...SST 6000 3000 AC INPUT CABLE eF 785 INSTALLATION MANUAL 71 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Страница 75: ...DUAL 24VDC SUPPLY CABLE J5 eF 785 INSTALLATION MANUAL 73 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Страница 77: ...24VDC DIST CABLE IOC APC P9 P11 eF 785 INSTALLATION MANUAL 75 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Страница 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Страница 81: ...EXTENSION CHEATER PLUG P13 eF 785 INSTALLATION MANUAL 79 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...