DN
- The DN configuration supports DC powered motor drives in the
Main Area only, but no Load Area. In the DN configuration, the J8
circuits, normally reserved for Load area functionality, may be used as
additional Main Area circuits. Example part number:
EF-785-
DN
xx-xxx-x.
J2
P7B
P7A
J8B*
J8A*
P6
Main
Load
Safety Control
48-90VDC
Supply
CB1
P2
Interlock
switches
E-Stop
switches
To general hazardous
loads
To Main Area
DC Motor Drives
AC
DC
DN Configuration
Door locks
* see text
Simplified power flow schematic-DN
PURCHASING A UNIT FOR DEVELOPMENT
For the purposes of machine design and development, Teknic
recommends that you initially order the
AA
configuration. This leaves
your design options open (the
AA
configuration can do the work of any
of the other four power configurations). Once your machine design is
stable, order only the options you need.
EMI
FILTERING
O
PTIONS
The eF-785 offers two available EMI filtering options, two-stage
(D)
and
four-stage
(Q)
.
T
WO
-S
TAGE
(D
UAL
)
F
ILTERING
The basic level of EMI filtering offered for the eF-785 is two-stage (
D
ual)
filtering indicated by the letter
D
in the position shown above. The 2-
stage option is standard in configurations where only DC powered motor
drives are present in the machine (i.e. power control configurations DD
or DN). This (lesser) magnitude of filtering is usually sufficient for
machines in which there are no AC powered motor drives present.
F
OUR
-S
TAGE
(Q
UAD
)
F
ILTERING
Quad or four-stage filtering is specified by the letter
Q.
Four-stage
filtering comes standard on all eF-785s configured for AC powered motor
drives (i.e. power configurations AA, AD, and AN). With this level of
filtering, your machine can meet EN 50081-2 and EN 50082-2 for
emissions and susceptibility without individual line filters for each servo
drive (typically a notable cost savings).
e F - 7 8 5
I
N S T A L L A T I O N
M
A N U A L
15
T
EKNIC
,
I
NC
F
AX
(585)784-7460
V
OICE
(585)784-7454
Содержание EF-785
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Страница 67: ...48 90VDC MAIN AREA TO SST P7A P7B eF 785 INSTALLATION MANUAL 65 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Страница 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Страница 71: ...AC SERVO POWER CABLE MAIN AREA P3 eF 785 INSTALLATION MANUAL 69 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Страница 73: ...SST 6000 3000 AC INPUT CABLE eF 785 INSTALLATION MANUAL 71 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Страница 75: ...DUAL 24VDC SUPPLY CABLE J5 eF 785 INSTALLATION MANUAL 73 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Страница 77: ...24VDC DIST CABLE IOC APC P9 P11 eF 785 INSTALLATION MANUAL 75 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Страница 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Страница 81: ...EXTENSION CHEATER PLUG P13 eF 785 INSTALLATION MANUAL 79 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...