46
V
E R S I O N
1 . 4 2
/
A
U G U S T
2 6 ,
2 0 0 5
I
NTERLOCK
S
WITCHES
Interlock switch selection considerations
•
•
•
•
The switch must be a DPST type switch, with normally closed, and
positively guided contacts. (refer to EN 1088, EN292-1 section
3.22.4, and EN 292-2 section 3.5)
Mounting the interlock switches
The interlock switch must be mounted in such a way that prevents
the actuator key from being latched into the interlock switch
while the gate/guard is in the open position (i.e. bypassing the
interlocking system).
The actuator key should be mounted to the gate/guard using
tamper-resistant hardware/screws.
Refer to EN 1088 for information regarding selection and
mounting of interlock switches.
Suggested Interlock Switch (consists of 3 separate parts)
Euchner/GP1-538HA-M (interlock switch with 2 NC force-guided
contacts)
Euchner/059 440 (metal hinged latch actuator key)
Euchner/M20CGP (cable entry gland nut)
Suggested Euchner Interlock Switch
G
UARD
-L
OCKS
Guard-lock selection considerations
•
•
•
The switch must be a DPST type switch, with normally closed, and
positively guided contacts. (refer to EN 1088, EN292-1 section
3.22.5, and EN 292-2 section 3.5)
The guard-lock must operate in such a way that the actuator key is
locked when inserted into the guard-lock when no power is applied,
and the actuator key may only be removed when power is applied to
the device. (refer to EN 1088 section 4.2.2)
Mounting the Guard-locks
The guard-lock must be mounted in such a way that prevents the
actuator key from being latched into the guard-lock while the
gate/guard is in the open position (i.e. bypassing the
interlocking/guard-locking system).
Содержание EF-785
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...APPENDIX C CABLE DIAGRAMS 48 90VDC LOAD AREA TO SST J8A J8B 64 VERSION 1 42 AUGUST 26 2005 ...
Страница 67: ...48 90VDC MAIN AREA TO SST P7A P7B eF 785 INSTALLATION MANUAL 65 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 68: ...48 90VDC LOAD AREA TO ISC J8A J8B 66 VERSION 1 42 AUGUST 26 2005 ...
Страница 70: ...AC SERVO POWER CABLE LOAD AREA J4 68 VERSION 1 42 AUGUST 26 2005 ...
Страница 71: ...AC SERVO POWER CABLE MAIN AREA P3 eF 785 INSTALLATION MANUAL 69 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 72: ...SST 6000 3000 DC POWER JUMPER CABLE 70 VERSION 1 42 AUGUST 26 2005 ...
Страница 73: ...SST 6000 3000 AC INPUT CABLE eF 785 INSTALLATION MANUAL 71 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 74: ...SINGLE 24VDC SUPPLY CABLE J5 72 VERSION 1 42 AUGUST 26 2005 ...
Страница 75: ...DUAL 24VDC SUPPLY CABLE J5 eF 785 INSTALLATION MANUAL 73 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 76: ...70 90VDC SUPPLY CABLE SST EMF75 P6 74 VERSION 1 42 AUGUST 26 2005 ...
Страница 77: ...24VDC DIST CABLE IOC APC P9 P11 eF 785 INSTALLATION MANUAL 75 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 78: ...40VDC POWER TAP DISTRIBUTION CABLE P18 76 VERSION 1 42 AUGUST 26 2005 ...
Страница 80: ...INTEGRATION TESTING CHEATER PLUG SAFETY CONTROL CKTS P12 78 VERSION 1 42 AUGUST 26 2005 ...
Страница 81: ...EXTENSION CHEATER PLUG P13 eF 785 INSTALLATION MANUAL 79 TEKNIC INC FAX 585 784 7460 VOICE 585 784 7454 ...
Страница 82: ...INPUT POWER CABLE J2 80 VERSION 1 42 AUGUST 26 2005 ...