![TECO-Westinghouse MA7200 PLUS Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/teco-westinghouse/ma7200-plus/ma7200-plus_installation-manual_1072545008.webp)
MA7200 PLUS Operating Manual
TECO – Westinghouse Motor Company Front Cover & Digital Operator Removal
Cont.
(B) 230V: 3-10HP, 460V: 3-10HP and 575V: 1 -10 HP
MA7200-2003-N1
MA7200-4003-N1
MA7200-5001-N1
MA7200-5007-N1
MA7200-2005-N1
MA7200-4005-N1
MA7200-5002-N1
MA7200-5010-N1
MA7200-2007-N1
MA7200-4007-N1
MA7200-5003-N1
MA7200-2010-N1
MA7200-4010-N1
MA7200-5005-N1
■
Removing the digital operator
Remove screws a and b. Press the lever on the side of the
Digital Operator in the direction of arrow 1 to unlock the Digital
Operator. Carefully disconnect the RS-232 cable connector on
the back side of the LCD digital operator and lift the Digital
Operator in the direction of arrow 2 to remove.
1
2
a
b
Front Cover
LCD Digital Operator
■
Removing the front cover
Press the left and right sides of the front cover in the directions
of arrow 1 and lift the bottom of the cover in the direction of
arrow 2 to remove.
1
2
1
Front
Cover
c
RS-232
Cable
Connector
■
Mounting the front cover and Digital Operator
Insert the tab of the upper part of front cover into the groove of
the inverter housing and press the lower part of the front cover
onto the inverter until it snaps into place.
Connect the RS-232 cable connector to the back side of the
Digital Operator and hook the one side of the Digital Operator
on the front cover in the direction of arrow 1.
Press the digital operator in the direction of arrow 2 until it
snaps into place and then secure with c and d.
1
2
Front
Cover
c
b
a
d
e
Digital
Operator
RS-232
Cable
Connector
Cont.