MA7200 PLUS Operating Manual
TECO – Westinghouse Motor Company Cn-14 – Cn-34
Parameter Summary
Cont
Function
Parameter
No.
Name
LCD display
(English)
Setting range
Setting
Unit
Factory
Setting
Ref.
DC
Braking
Function
Cn-14
DC Injection Braking
Starting Frequency
Cn-14= 01.5Hz
C Braking Start F
0.1 - 10.0 Hz
0.1Hz
1.5Hz
Sec.
9.2.2
Cn-15
DC Braking Current
Cn-15= 050%
DC Braking Current
0 - 100%
1%
50%
Cn-16
DC Injection Braking
Time At Stop
Cn-16= 00.5s
DC Braking Stop
Time
0.0 - 25.5s
0.1s
0.5s
Cn-17
DC Injection Braking
Time At Start
Cn-17= 00.0s
DC Braking Start
Time
0.0s
Frequency
Limit
Cn-18
Frequency Command
Upper Bound
Cn-18= 100%
Freq.Cmd. Up Bound
0 - 109%
1%
100%
Cn-19
Frequency Command
Lower Bound
Cn-19= 000%
Freq. Cmd. Low
Bound
0%
Frequency
Jump
Cn-20
Frequency Jump
Point 1
Cn-20= 000.0Hz
Freq. Jump 1
0.0 - 400.0Hz
0.1Hz
0.0Hz
Cn-21
Frequency Jump
Point 2
Cn-21= 000.0Hz
Freq. Jump 2
Cn-22
Frequency Jump
Point 3
Cn-22= 000.0Hz
Freq. Jump 3
Cn-23
Jump Frequency
Width
Cn-23= 01.0Hz
Freq. Jump Width
0.0 - 25.5Hz
0.1Hz
1.0Hz
Cn-24
Number of Auto
Restart Attempt
Cn-24= 00
Retry Times
0 - 10
1
0
Cn-25
Stall Prevention
During Acceleration
Cn-25= 170%
Acc. Stall
30 - 200%
1%
170%
Cn-26
Stall Prevention
During Running
Cn-26= 160%
Run Stall
160%
Cn-27
Communication Fault
Detection Time
Cn-27=01.0s
Comm. Flt Det. Time
0.1 - 25.5s
0.1s
1s
Cn-28
LCD Digital Operator
Display Unit
Cn-28= 00000
Operator Disp. Unit
0 -39999
1
0
Cn-29
Freq. Agree
Detection Level
During Accel.
Cn-29= 000.0Hz
Acc. Freq. Det.Level
0.0 - 400.0Hz
0.1Hz
0.0Hz
Cn-30
Freq. Agree
Detection Level
During Decel.
Cn-30= 000.0Hz
Dec. Freq. Det. Level
Cn-31
Frequency Agree
Detection Width
Cn-31= 02.0Hz
F Agree Det. Width
0.1 - 25.5Hz
0.1Hz
2.0Hz
Cn-32
Excess Load
Detection Level
Cn-32= 160%
Excess Load Level
0 - 200%
1%
160%
Cn-33
Excess Load
Detection Time
Cn-33= 00.1s
Excess Load
Det.Time
0.0 - 25.5s
0.1s
0.1s
Cn-34
Carrier frequency
setting
Cn-34= 6
Carry_Freq Setting
1- 6
1
6
Cont.