S.p.A.
ITEM TE550
Instruction manual
33/92
THICK. MIN
This parameter fixes a lower limit for the minimum thickness of the material located in
between the electrodes. Before starting the weld, the measurement of the thickness of the
material present between the electrodes should be greater than the minimum limit. Otherwise,
an error message is displayed.
Activate this parameter by setting QUALITY - T in THICK or in TH+ID, otherwise the
parameter will not be displayed during programming.
THICK. MAX
This parameter fixes a higher limit for the maximum thickness of the material located in
between the electrodes. Before starting the weld, the measurement of the thickness of the
material present between the electrodes should be less than the maximum set limit.
Otherwise, an error message is displayed.
Activate this parameter by setting QUALITY - T in THICK or in TH+ID, otherwise the
parameter will not be displayed during programming.
IDENT. MIN
This parameter fixes a lower limit for the minimum electrode indentation measurement at the
end of the weld. The measurement of the indentation value should be greater than the set
limit at the end of the weld. Otherwise, an error message is displayed.
Activate this parameter by setting QUALITY - T in IDENT or in TH+ID, otherwise the
parameter will not be displayed during programming.
IDENT. MAX
This parameter fixes a higher limit for the maximum electrode indentation measurement at the
end of the weld. The measurement of the indentation value should be less than the set limit at
the end of the weld. Otherwise, an error message is displayed.
Activate this parameter by setting QUALITY - T in IDENT or in TH+ID, otherwise the
parameter will not be displayed during programming.
PRES. MIN
This parameter fixes a minimum limit for the pressure measurement at the end of the squeeze
phase. The measured pressure value must be greater than the set limit otherwise an error
message will be displayed.
This parameter may be activated by setting
INPUT VE/PRE
(available in the
FEATURES
MENU
)
in
PRE
otherwise the parameter
is not displayed when programming.
PRES. MAX
This parameter fixes a maximum limit for the pressure measurement at the end of the
squeeze phase. The measured pressure value must be lower than the set limit otherwise an
error message will be displayed
This parameter may be activated by setting
INPUT VE/PRE
(available in the
FEATURES
MENU
)
in
PRE
otherwise the parameter
is not displayed when programming.