S.p.A.
ITEM TE550
Instruction manual
2.9
- FEATURES MENU
-TE550 VER. 3.31--
SETUP MENU
STEPPER MENU
>FEATURES MENU
The features menu contains the parameters that describe the complexity and typology of the
welder on which the control unit works. Due to their importance, access to this menu is
protected by a code.
ENTER ACCESS CODE
FOR FEATURES MENU
- - - - -
If the user is not authorized to enter this menu and does not know the access code, the
following message is displayed:
WRONG CODE
TRY AGAIN!
The parameters can be edited only after having typed in the access code.
Keep in mind that only skilled personnel are permitted to edit the following
parameters to prevent damage to people or equipment.
PARAMETER
PARAMETER DESCRIPTION
VALUE RANGE
FIRST INSERT.
1st Insertion delay
01 –99
SERIAL COM.
Serial communication
232 – 485 – USB – OFF
NETWORK ADDRESS Network address
01 – 31
COIL RATIO
Rogowski ratio
X 0.5 – X1 –X5 – X10
LOCK/END OUT
Output function
END – LOCK
FUNCTION RIC6-7
Recall function 6 and 7
RIC – BIC
LOW FORCE SQ.
Low force squeeze
ON - OFF
FORGE
Forging
ON – OFF
PROP. VALVE
Proportional valve
ON - OFF
PRESSURE RATIO
Proportional ratio
0.1 – 2.0
AUTORETAIN
Start Autoretain
ON – OFF
NC CONTACTS
Also NC functions of the cycle starts
OFF
SEAM WELD MODE
Spots / seams
ON – OFF
BUTT WELD MODE
Butt weld function
ON – OFF
SER. SPOT MODE
High speed function
ON – OFF
CASCADE MODE
Electric cascade function
ON – OFF
ADJUST POWER%
Power map correction
00 - 10
WELD / NO WELD
WELD / NO WELD management
INT – EXT – BOTH
THICK SENSOR
Position sensor function
ON – OFF
EV LOCK ON ERR.
Head lock function in case of error
ON – OFF – KEY
INPUT VE/PRE
Input selector VE/PRE
VE – PRE
VOLTAGE RANGE
Electrodes voltage capacity
5V – 10V – 20V
BACKUP USB
Usb backup function
<+>
RESTORE USB
Usb restore function
<+>
SET DATE-TIME
Usb set calendar-clock
<+>
43/92