S.p.A.
ITEM TE550
Instruction manual
TABLE CONSTANT CURRENT OPERATING MODE PARAMETERS
PROGRAM DATA
>PROGRAM N. 001
WORKING MODE IK
CONTROL MODE DEG
PARAMETER VALUE
RANGE
PROGRAM N.
001 - 250
WORKING MODE
IK
CONTROL MODE *
NO
QUALITY – T *
OFF
SQUEEZE 1
00.5 - 99.5 cycles
SQUEEZE
00.5 - 99.5 cycles
PRESSURE
00.5 – 10.0 bar
FORGE DELAY
00 - 99 cycles
FORG.PRESS.
00.5 - 10.0 bar
PRE-WELD
00.0 - 99.5 cycles
PRE-POWER
05 - 99 %
COLD 1
00 - 50 cycles
SLOPE UP
00 - 25 cycles
WELD
00.5 - 99.5 cycles
CURRENT
00.5 - 90.0 kA
IMPULSE N.
01 – 09
COLD 2
00 – 50 cycles
SLOPE DOWN
00 – 25 cycles
COLD 3
00 – 50 cycles
POST-WELD.
00.0 – 99.5 cycles
POST-POWER
05 – 99 %
HOLD TIME
00.5 - 99.5 cycles
OFF TIME
00.0 - 99.5 cycles
CONTROL MODE *
CURR
CURR. MIN
0.5 - 90.0 kA
CURR. MAX
0.5 - 90.0 kA
CONTROL MODE *
DEG
ANGLE MIN
005°-180°
ANGLE MAX
005°-180°
CONTROL MODE *
ALL
CURR. MIN
0.5 - 90.0 kA
CURR. MAX
0.5 - 90.0 kA
ANGLE MIN
005°-180°
ANGLE MAX
005°-180°
QUALITY - T*
THICK
THICK. MIN
00.00 – 60.00 mm
THICK. MAX
00.00 – 60.00 mm
21/92