Instruction manual
ITEM TE550
S.p.A.
58/92
LINEAR SENSOR
This parameter activates or deactivates the linear position sensors. If a sensor initialization
error occurs, the parameter commutates to OFF automatically. Sensor identification
parameters are not deleted.
The enabling of the position sensors makes available the measurements relative both to the
initial thickness of the sheets to be welded and the indentation of the electrode at the end of
the weld, and relative limits.
SENSOR S/N_P1:
This parameter contains the first part of the serial number of the linear sensor, which can be
read on the sensor's body.
SENSOR S/N_P2:
This parameter contains the second part of the serial number of the linear sensor, which can
be read on the sensor's body.
SENSOR ID CAN:
This parameter is for setting the sensor's ID in the CAN network. In order to work efficiently,
the sensors present in the CAN network must have univocal identifiers.
DELAY IDENT.
This parameter specifies the delay, in mS, that the system must wait after the weld current
flow to measure the coordinate with which to obtain the electrode indentation value during the
weld.
Below is explained the procedure for adjusting the DELAY IDENT. parameter.