AMMETER CAP.
This parameter indicates the ammeter capacity of the control unit. Keep in mind that the
capacity refers to simple harmonic currents and as such overflow conditions might occur even
with effective current values lower than the nominal value of the carrying capacity (please,
also consult the COIL RATIO parameter relevant to the sensitiveness of the connected
transducer, in the SET UP MENU).
LANGUAGE
With this parameter the user programs the language in which the control unit should display
both the parameters to be set and the error messages.
One may select the following languages: ITALIAN – ENGLISH – SPANISH – GERMAN –
FRENCH – HUNGARIAN – PORTUGUESE – SWEDISH – DUTCH – POLISH.
PRE-WELD
By setting it on ON, it activates the following parameters: PRE-WELD, PRE-POWER and
COLD 1 in all the programs.
POST-WELD
By setting it on ON, it activates the following parameters: SLOPE DOWN, COLD 3, POST-
WELD and POST-POWER in all the programs.