The IMPULSE N. parameter indicates the number of impulses used for carrying out the
welding process. The duration of each impulse corresponds to the time set in weld parameter
(WELD).
The maximum pulse number which can be carried out during a welding cycle varies according
to the BUTT WELD MODE parameter adjustment (present in the
FEATURES
menu). If it is
set on OFF, the maximum programmable pulse number is equal to 9 while if it is set on ON it
is equal to 50.
COLD 2
The COLD 2 parameter is used in the pulse operating mode; it indicates the time that elapses
from a welding impulse to the next one. When the impulse number is set to zero, the cold time
2, even if programmed, is not carried out.
SLOPE DOWN
The SLOPE DOWN parameter is a welding time that is added at the end of the welding
process: it enables to decrease the welding current from the value set at POWER or at
CURRENT down to the minimum value. The slope down inclination is automatically calculated
by the microprocessor according to the set values. The SLOPE DOWN time is always added
to the welding time.
This parameter may be activated through the relevant function in the
SETUP MENU
.
COLD 3
The COLD 3 parameter indicates the time that elapses from the WELD time to the POST-
WELD time.
This parameter may be activated through the relevant function in the
SETUP MENU
.
POST-WELD
The POST-WELD parameter indicates the duration of a current flow that can be carried out
after the welding time in. This parameter is expressed by three digits since it can be adjusted
with half-cycle precision. If this parameter is set to 0 the post-weld is not carried out. The
post-weld is carried out with the current adjustment set in the POST-POWER parameter.
This parameter may be activated through the relevant function in the
SETUP MENU
.
POST-POWER
The value expressed in this parameter indicates the post-welding power. This parameter may
be activated through the relevant function in the
SETUP MENU
.
POWER 3
The value expressed in this parameter indicates the second power which can be recalled by
means of the proper input in seam operating mode.
This parameter is only displayed when SEAM WELD MODE on ON is selected.
CURRENT 3
The value expressed in this parameter indicates the second current which can be recalled by
means of the proper input in seam operating mode.
This parameter is only displayed when SEAM WELD MODE on ON is selected.