S.p.A.
ITEM TE550
Instruction manual
FUNCTIONING DESCRIPTION
When the squeeze time is over, if the pressure value measured by the control unit is within
the limits set in the program, then the TE550 proceeds with the welding phase itself.
Otherwise, as long as there is a start cycle, the control unit will display a screen showing the
measured pressure value (PRESSURE) and the limits set in the program (PRESS. MIN and
PRESS. MAX).
PRG 005 SPOT 01234
PRESSURE 03.8 bar
PRESS. MIN 01.5 bar
PRESS. MAX 02.5 bar
During this phase, should the start cycle signal be removed, the control unit stops showing an
error when measuring the pressure
ERR 0129
PRESSURE SENSOR
MEASURE ERROR
And activates the output signal WRONG.
The error will be cleared and the WRONG signal deactivated by means of the CLEAR
key
or by means of the ERROR CLEAR input on the relevant expansion board.
83/92