TechnoAlpin M20
- 3 -
THE JET RINGS
On the M20 jet ring you find (viewed from the front):
o
12 fixed jets (FJ)
o
6 nucleators (N)
o
12 switchable jets (numbered V1….V12)
o
6 valve motors (numbered V
mot1…..Vmot6)
1.1
A
UTOMATIC
R
EGULATION
Automatic regulation is accomplished through the sensor set, the control unit and the valve cards. The snow
machine sets itself according to the given environmental conditions to produce the required snow quality. If an
automatic hydrant of the
Hydromat SE
is installed, the snow machine can also independently set the water
pressure to the required operating pressure.
Automatic Hydrant recognition:
24 V extern
Automatic Hydrant present
Extern Start (if available)
Extern Stop (if available)
Hydromat 200 present
Hydrant on
Hydrant off
24 V Shaft recognition
white/green (3)
Shaft recognition
canal 1
yellow/brown (2)
RS 485 yellow
red(1)
RS 485 green
RS 485 brown
RS 485 white
r
E-motor present
Shaft recognition
channel 2
0 V extern
white/yellow (4)
red/green (7)
pink (8)
blue (9)
yellow (10)
brown (12)
green (11)
white (13)
grey (14)
violet(15)
black(16)
grey/pink (5)
brown/green (6)
Содержание M 20 AT