Proline Promass F 500 EtherNet/IP
Technical data
263
SI units
DN
1:1
1:10
1:20
1:50
1:100
1:500
[mm]
[kg/h]
[kg/h]
[kg/h]
[kg/h]
[kg/h]
[kg/h]
8
2
000
200
100
40
20
4
15
6
500
650
325
130
65
13
25
18
000
1
800
900
360
180
36
40
45
000
4
500
2
250
900
450
90
50
70
000
7
000
3
500
1
400
700
140
80
180
000
18
000
9
000
3
600
1
800
360
100
350
000
35
000
17
500
7
000
3
500
700
150
800
000
80
000
40
000
16
000
8
000
1
600
250
2
200
000
220
000
110
000
44
000
22
000
4
400
US units
DN
1:1
1:10
1:20
1:50
1:100
1:500
[inch]
[lb/min]
[lb/min]
[lb/min]
[lb/min]
[lb/min]
[lb/min]
³⁄₈
73.50
7.350
3.675
1.470
0.735
0.147
½
238.9
23.89
11.95
4.778
2.389
0.478
1
661.5
66.15
33.08
13.23
6.615
1.323
1½
1
654
165.4
82.70
33.08
16.54
3.308
2
2
573
257.3
128.7
51.46
25.73
5.146
3
6
615
661.5
330.8
132.3
66.15
13.23
4
12
860
1
286
643.0
257.2
128.6
25.72
6
29
400
2
940
1
470
588
294
58.80
10
80
850
8
085
4
043
1
617
808.5
161.7
Accuracy of outputs
The outputs have the following base accuracy specifications.
Current output
Accuracy
±5 µA
Pulse/frequency output
o.r. = of reading
Accuracy
Max. ±50 ppm o.r. (over the entire ambient temperature range)
Repeatability
o.r. = of reading; 1 g/cm
3
= 1 kg/l; T = medium temperature