Diagnostics and troubleshooting
Proline Promass F 500 EtherNet/IP
236
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
910 Tubes not oscillating
1. Check electronic
2. Inspect sensor
0x1000050
Status signal
F
Diagnostic behavior
Alarm
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
912 Medium inhomogeneous
1. Check process cond.
2. Increase system pressure
• 0x80000C4
• 0x80000DF
• 0x8000115
• 0x8000162
Status signal
S
Diagnostic behavior [from the
factory]
Warning
1)
Diagnostic behavior can be changed.
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
913 Medium unsuitable
1. Check process conditions
2. Check electronic modules or
sensor
0x80000CD
Status signal
S
Diagnostic behavior [from the
factory]
Alarm
1)
Diagnostic behavior can be changed.
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
941 API temperature out of specification
1. Check process temperature with
selected API commodity group
2. Check API related parameters
0x8000380
Status signal
S
Diagnostic behavior
Alarm
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
942 API density out of specification
1. Check process density with
selected API commodity group
2. Check API related parameters
0x800033B
Status signal
S
Diagnostic behavior
Alarm