Example: Val

ve preset temperature: 50°C 

 

Hysteresis: 2°C 

 

Valve stop: 50°C 

 

Valve opening: 48°C 

 

Valve closing: 52°C

 

 

When the set temperature is 50°C and the hysteresis is 2°C, the valve will stop in one position when the temperature 
reaches 50°C, when the temperature drops to 48°C

it will start to open and when it reaches 52°C

, the valve will start 

to close in order to lower the temperature. 
 

 

Valve type 

 This option enables the user to select the following valve types: 

 

 

CH valve

 - set when we wish to control the temperature in the CH circuit using the valve sensor. The valve sensor 

shall be placed downstream of the mixing valve on the supply pipe. 
 

 

Floor valve

 - set when we wish to adjust the temperature on the underfloor heating circuit. The floor type protects 

the floor system against excessive temperatures. If the type of valve is set as CH and it is connected to the floor 
system, it may lead to damage to the floor system. 
 

 

Return protection

 - set when we wish to adjust the temperature at the return of our installation using the return 

sensor. Only return and boiler sensors are active in this type of valve, and the valve sensor is not connected to the 
controller. In this configuration, the valve protects the boiler's return from cold temperature as a priority, and if 
the 

Boiler protection

 function is selected, it also protects the boiler from overheating. If the valve is closed (0% 

open), the water flows only in a short circuit, while the full opening of the valve (100%) means that the short circuit 
is closed and the water flows through the entire central heating system. 

 

CAUTION 

If the 

Boiler  Protection

 

is off, the CH temperature will not  affect the opening of the valve. In 

extreme cases, the boiler may overheat, so it is recommended to configure the boiler protection 
settings. 
For this type of valve, refer to the 

Return Protection Screen.

 

 

 

Cooling 

-  set  when  we  want  to  adjust  the  temperature  of  the  cooling  system  (the  valve  opens  when  the  set 

temperature is lower than the temperature of the valve sensor). 

Boiler protection and Return protection

 do not 

work in this type of valve. This type of valve operates despite the active 

Summer mode

, while the pump operates 

using  the  shutdown  threshold.  In  addition,  this  type  of  valve  has  a  separate  heating  curve  incorporated  as  a 
function of the 

Weather sensor

 

 

Opening in CH calibration 

 When this function is enabled, the valve starts its calibration from the opening phase. 

This function is only available when the valve type is set as a 

CH Valve

 

 

Floor heating - summer 

 This function is only visible after selecting the valve type as 

Floor Valve

. When this function 

is enabled, the floor valve will operate in the 

Summer Mode

 

 

Weather control

 

 For the weather function to be active, place the external sensor in a not insolated location, one 

that is not exposed to atmospheric influences. After installing and connecting the sensor, switch on the 

Weather 

control

 function in the controller menu. 

CAUTION 

This setting is not available in the 

Cooling

 and 

Return Protection

 Modes. 

 

 

Содержание EU-L-X WiFi

Страница 1: ...EU L X WiFi...

Страница 2: ...4 5 Manual mode 25 4 6 External sensor 25 4 7 heating stopping 25 4 8 Potential free contact 26 4 9 Pump 26 4 10 Heating cooling 26 4 11 Anti stop settings 26 4 12 Maximum humidity 26 4 13 Language 2...

Страница 3: ...The regulator should not be operated by children WARNING The device may be damaged if struck by a lightning Make sure the plug is disconnected from the power supply during storm Any use other than spe...

Страница 4: ...number of functions support for EU R 12b EU R 12s and EU F 12b cable regulators support for floor temperature sensors support for external sensors and weather controls support for wireless window sens...

Страница 5: ......

Страница 6: ...connections Before working on the controller disconnect its power supply and secure it against accidental switching on CAUTION Incorrect wiring may damage the controller An illustrative diagram showi...

Страница 7: ...d into the right terminal of the sensor connector as seen from the front of the controller and depicted in attached images The second terminal of the capacitor is screwed into the terminal of the left...

Страница 8: ...r in the ON position in the controller and the last of the regulators When connecting regulators to a controller located in the middle of the transmission line terminate switch the jumper to the ON po...

Страница 9: ...ime can be adjusted from the network automatically Step 4 Configure temperature sensors room regulators In order for the EU L X WiFi controller to support a given zone it must receive information abou...

Страница 10: ...s the operation parameters between the zones 3 button used to browse the menu functions or increase the value of the edited parameters This button also switches the operation parameters between the zo...

Страница 11: ...cooling depending on the mode the digit flashes If an alarm occurs in a given zone an exclamation mark will be displayed instead of a digit To view the current operating parameters of a specific zone...

Страница 12: ...ature The set temperature in the zone results from the settings of a specific mode of operation in the zone i e the weekly schedule However it is possible to turn off the schedule and set a separate t...

Страница 13: ...ing the MENU button Use the MENU button to go to the settings of the time intervals and the set temperature that will be valid for the specified time interval set it using the arrows confirm with the...

Страница 14: ...steresis is 1 C The room sensor will start to indicate room underheating after the temperature drops to 22 C Calibration Room sensor calibration is carried out during assembly or after a longer period...

Страница 15: ...s information to automatically activate the heating in advance of the time required to reach the set temperatures This system does not require any involvement on the part of the user and precisely res...

Страница 16: ...n the zone temperature reaches the set point Once the set point is reached the temperature in the zone will start to drop When it reaches 21 C set temperature minus hysteresis value the actuator will...

Страница 17: ...tration an additional Information function appears where the user can view the sensor parameters e g battery status range etc It is also possible to delete a given sensor or all at the same time 4 1 8...

Страница 18: ...llation from overheating 4 2 ADDITIONAL CONTACTS The function allows you to handle additional contacts First of all it is necessary to register such a contact 1 6 pcs To do this select the Registratio...

Страница 19: ...e Calibration This function can be used to calibrate the built in valve e g after prolonged use During calibration the valve is set to a safe position i e for the CH valve and the Return protection ty...

Страница 20: ...y in a short circuit while the full opening of the valve 100 means that the short circuit is closed and the water flows through the entire central heating system CAUTION If the Boiler Protection is of...

Страница 21: ...When this function is checked the controller will operate according to the Room regulator temperature lower parameter Room regulator temp lower In this setting set the value by which the valve will l...

Страница 22: ...take into account the Self of the valve module or the Main sensor Only in slave mode Boiler protection This provides protection against excessive CH temperature and is intended to prevent dangerous i...

Страница 23: ...e deviations set are in the range of 10 C To enable weekly control select and check Mode 1 or Mode 2 Detailed settings of these modes can be found in the following sections of the submenu Set Mode 1 a...

Страница 24: ...on The user can control the operation of various devices and change some parameters using the emodul pl application The device has a built in Internet module After switching on the Internet module and...

Страница 25: ...to 10 C with a step of 0 1 C In the case of a wireless sensor the subsequent parameters relate to the range and level of the battery 4 7 HEATING STOPPING Function to prevent actuators from turning on...

Страница 26: ...operating mode Heating all zones are heated Cooling all zones are cooled Automatic the controller switches the mode between heating and cooling based on the two state input 4 11 ANTI STOP SETTINGS Thi...

Страница 27: ...sensor Replace the sensor with a new one or contact the service staff if necessary No communication with sensor wireless regulator No range No battery Flat battery Put the sensor regulator in a differ...

Страница 28: ...the controller has been installed properly Replace the batteries Calibrate actuator again by holding the communication button until the third flash of green light Call the service staff ERROR 3 Calib...

Страница 29: ...arried out by a qualified installer After changing the software it is not possible to restore the previous settings Do not turn off the controller while updating the software IX TECHNICAL DATA AC1 loa...

Страница 30: ...equipment implementing provisions of Directive EU 2017 2102 of the European Parliament and of the Council of 15 November 2017 amending Directive 2011 65 EU on the restriction of the use of certain ha...

Страница 31: ......

Страница 32: ......

Отзывы: