5-7
EO18-33002A
5. DIAG. TEST OPERATION
NOTES:
1.
If the maintenance counter printing results in an error, the printer will display the
error message and stop printing. The error status can be cleared by the [PAUSE]
key, however, the display will return to the initial display “<1> DIAG. V1.0A”.
Printing is not automatically resumed after the error is cleared.
2.
Both label and tag paper can be used for printing.
5.2.2
Maintenance Counter Printing
The data from
1
to
I
on a sample print is printed. This data is the printer status and the
value set in the parameter setting mode.
5.2 SELF TEST MODE
Power off
Press the [PAUSE] key.
Press the [PAUSE] key.
Press the [PAUSE] key.
Select the sensor type from those
at the right by pressing the
[FEED] key or [RESTART] key.
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
The result of the self test
is printed. After printing,
the initial display will be
shown.
TRANSMISSIVE
REFLECTIVE
(black mark sensor)
NONE
(consecutive form)
(feed gap sensor)
The printer is checking or printing
the status
< 1
D I A G .
V 1 . O A
>
S E
S O R
T R A N S .
N
M A
N T E N A N C E
C O N T
I
C H
C K I N G
&
P R I N T
E