3-4
3. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
EO18-33002A
NOTE:
Care must be taken when handling the ribbon.
6) Take up any slack in the ribbon and insert the ribbon module into the print head mechanism.
NOTE:
The ribbon module should be positioned in order of yellow, cyan, magenta and black as viewed
from the front of the printer.
7) Turn the head lever to the LOCK position then once again take up any ribbon slack.
8) Close the top cover.
Fig. 3-7
Fig. 3-6
Notch
Protrusion
Ribbon Shaft
Ribbon Feed Core
Ribbon Stopper
Ribbon Module
Ribbon Winding Core
Print Head Machanism
Ribbon Module
3) Insert the ribbon onto the ribbon shaft so that the notch of the ribbon core aligns with the protrusion
on the ribbon shaft.
4) Attach the ribbon stopper to the ribbon shaft.
5) Unroll about 30 cm of the ribbon then place the ribbon module on the ribbon. Set the ribbon feed
core first then the ribbon winding core on the ribbon module in place.
3.2 RIBBON MODULE (CB-1004-QM)