5-38
EO18-33002A
5. DIAG. TEST OPERATION
(Revision Date: Dec. 20, 2000)
5.3 PARAMETER SETTING MODE
5.3.6
Platen Speed Fine Adjustment Mode
If a color misalignment occurs due to paper thickness, elasticity, slack, etc., change the platen
speed to prevent the color misalignment.
Power off
Press the [FEED] key.
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
[FEED] key:
pressing the [FEED] key one
time is a -1 step change, up to
-60 steps. (See NOTE 2.)
< 1
D I A G .
V 1 . O A
>
< 2
P A R A M E T E R
S E T
>
[RESTART] key: pressing the [RESTART] key
one time is a +1 step change,
up to +60 steps.
(See NOTE 2.)
+ : Slower
— : Faster
Press the [PAUSE] key.
Press the [PAUSE] key.
Press the [FEED] key five time.
Press [PAUSE] key.
P O
I T I O N
S
P M
A D J .
+ 0
P M
A D J .
Press the [FEED] or
[RESTART] key to fine
adjust the platen motor
voltage. (See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Platen speed fine adjustment display
NOTES:
1.
This operation is effective when “AUTO” is selected in Section 5.3.5.4 Pulse
Motor Speed Selection.
2.
If a color misalignment occurs even after the platen speed fine adjustment, select
“104” for the pulse motor speed in Section 5.3.5.4 Pulse Motor Speed Selection.
3.
Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds
enables a fast forward.
4.
Max. fine adjustment
–
60 steps = Platen speed fine adjustment value.
5.
A changed motor voltage value is stored in memory by pressing the [PAUSE]
key.